  1. Hot panel change - Electrician Talk

    Nov 26, 2011 · House was just upgraded mid 2010 past ec was a hack, I've got a small mess to clean up 14/3 everywhere landed on multiple breakers some double landed etc. looking for any tips to …

  2. Recessed Panel Change to Surface Mount - Electrician Talk

    Sep 29, 2013 · How would you mount a new panel in front of where a recessed panel is? The panel box shown in these pics is of an old fused panel that is being replaced with a breaker panel. It is …

  3. Extending wires/Splicing in panel - Electrician Talk

    Sep 18, 2017 · What do you some of you do in the situation? I'm talking about being short 6"-12" , this happens on some upgrades where the panel/main breaker is bigger and the breakers start much …

  4. arc fault required for panel change out? - Electrician Talk

    Nov 21, 2007 · Changing out a 42 circuit, 200 amp panel from a home built in the late 90's. It had a 200 amp panel, the busbar went south under a loose A/C double pole breaker so I am replacing the …

  5. Panel: Replace Busbars? - Electrician Talk

    May 4, 2023 · SITUATION: Residential panel with an area of the busbar showing heat related discoloration. Busbars are not pitted or show other damage. ASSUMPTION: This was caused by a …

  6. convert 100-amp panel to 125? - Electrician Talk

    Mar 12, 2023 · I have a customer with a pole barn with a 100-amp Eaton BR 20-sp main breaker panel, model BR2020B100, currently on a 60-amp feeder from a service disconnect on a central pole (w …

  7. Installing breaker in a live panel - Electrician Talk

    May 14, 2009 · When you have a simple job at someone's house to do and part of it is installing a breaker for a dedicated circuit, do you call the PoCo to pull the meter (following their official rules)? …

  8. Replacing 200amp Panel with 225amp? - Electrician Talk

    Jul 4, 2024 · I'm replacing an old GE 200amp panel with a new 225amp Siemens load center. The meter base service disconnect is a 200amp breaker and the existing entrance cable is sized accordingly. …

  9. 200A panel but 100A service - Electrician Talk

    Feb 12, 2019 · The only way to do this is find a 200 amp panel that will take a 100 amp main breaker. The other option would be put in a 100 amp disco and then feed the 200 amp panel from there.

  10. how long does it take to swap out a panel? - Electrician Talk

    Jun 21, 2020 · That seems long. Using the old panel as a can, and making the new one next to it. both the same size. the less circuits the faster it is. I would do a residential, fuse to a breaker swap in 5 …